Корзина
19 отзывов
Интернет - магазин Siemens Simatic S7-1200
+74957722355
+74957722355

1756-OB32 Allen-Bradley модуль дискретного вывода 32 выхода =12/24В

  • В наличии
  • Код: 1756OB32

693 

+74957722355
1756-OB32 Allen-Bradley модуль дискретного вывода 32 выхода =12/24В
1756-OB32 Allen-Bradley модуль дискретного вывода 32 выхода =12/24ВВ наличии
693 
+74957722355
Купить

Описание

Модуль дискретного вывода для серии 1756 ControlLogix/GuardLogix System:

 

  • 32 выхода
  • Номинальное напряжение =12В или =24В

 

 

Варианты написания заказного номера:

1756OB32

1756-OB32

 

Технические данные:

1756-OB32 

Description: 1756 ControlLogix/GuardLogix System

I/O MODULES

DIGITAL DC OUTPUT MODULES (PLEASE SELECT NUMBER OF REMOVABLE TERMINAL BLOCKS AS ADDDED IN THE LIST.) 
10-31 VDC Output 32 Pts (36 Pin)

 

 

 

Technical Specifications - 1756-OB32

Outputs 32 (16 points/group)

Voltage category 12/24V DC source

Operating voltage range 10…31.2V DC

Output delay time

Off to On

On to Off

60 ìs nom/1 ms max

200 ìs nom/1 ms max

Current draw @ 5.1V 300 mA

Current draw @ 24V 2 mA

Total backplane power 1.58 W

Power dissipation, max 4.8 W @ 60 °C (140 °F)

Thermal dissipation 16.37 BTU/hr

Off-state leakage current per point, max 0.5 mA per point

On-state voltage drop, max 200 mV DC @ 0.5 A

Current per point, max 0.5 A @ 50 °C (122 °F) linear derating

0.35 A @ 60 °C (140 °F)

Current per module, max 16 A @ 50 °C (122 °F) linear derating

10 A @ 60 °C (140 °F)

Surge current per point, max 1 A for 10 ms per point, repeatable every 2 s @ 60 °C (140 °F)

Load current, min 3 mA per point

Scheduled outputs Synchronization within 16.7 s max, reference to the Coordinated System Time

States in Fault mode per point Hold last state, On or Off (Off is default)

States in Program mode per point Hold last state, On or Off (Off is default)

Isolation voltage 250V (continuous), basic insulation type, outputs-to-backplane, and output group-to-group

No isolation between individual group outputs

Module keying Electronic, software configurable

Fusing

Not protected. A fused IFM can be used to help protect outputs. See publication 1492-TD008. However, the ControlLogix

system has been agency certified using only the ControlLogix RTBs, that is, 1756-TBCH, 1756-TBNH, 1756-TBSH, and

1756-TBS6H. Any application that requires agency certification of the ControlLogix system that uses other wiring

termination methods can require application-specific approval by the certifying agency.

Removable terminal block 1756-TBCH

1756-TBS6H

RTB keying User-defined mechanical

Slot width 1

Wire category 1(1)

Enclosure type None (open-style)

North American temperature code T3C

IEC temperature code T3

  On-state voltage drop, max 200 mV DC @ 0.5 A  

Environmental Specifications - 1756-OB32

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

0…60 °C (32…140 °F)

Temperature, surrounding air, max 60 °C (140 °F)

Temperature, nonoperating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C (-40…+185 °F)

Relative humidity

IEC 60068-2-30 (Test dB, Unpackaged Damp Heat) 5…95% noncondensing

Vibration

IEC 60068-2-6 (Test Fc, Operating) 2 g @ 10…500 Hz

Shock, operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock) 30 g

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock) 50 g

Emissions IEC 61000-6-4

Характеристики

Основные
Производитель  Allen-Bradley
Страна производительСША
Вес0.3 кг
Гарантийный срок  12 мес

Информация для заказа

  • Цена: 693